Technology Transfer Network
Emission Measurement Center Spectral Database
Table 3-8. Validation of O2 and CO2 Measurement Data
Run O2 CO2 Calculated
No. (%d) (%d) Fo
--- ---- ---- ----------
1 15.1 3.3 1.76
2 15.1 3.3 1.76
3 15.1 3.4 1.71
Calculated Fo = (20.9-%O2) / %CO2
EPA Method 3 acceptance criteria,
Fo range: 1.64 - 1.88 for natural gas
|