Table 3-2. FTIR Results from Gas Samples


                                                 Effluent Volume            SO2                      Nitric Oxide
Location            Date    Run #   Sample Time    Flow (DSCFM)    ppm   uncertaint    lb/hr   ppm    uncertaint   lb/hr
----------------   -------  -----   ------------   ------------   -----  ----------   ------   ----   ----------   -----
Preheater Outlet   5/11/93    1      1641-1710       669,692      169.2     16.6      1131.1   36.5      62.8      114.2
(Baghouse Inlet)                     1741-1806                    169.4     15.6      1132.4   37.6      58.5      117.6
                                     1844-1852                    155.9     14.9      1042.2   36.5      57.6      114.2
                                    1900-1912(c)     353,766      181.8      4.7       642.0   46.4      28.3       76.7
                   5/12/93    2      1218-1240       702,305      173.0     12.0      1212.8   30.1      52.8       98.8
                                     1324-1348                    169.6     13.2      1188.9   28.3      58.3       92.9
                                    1452-1511(c)     359,538      167.0      5.0       599.3   42.2      28.6       70.9
                                     1521-1529                    155.5     11.8      1090.1   32.3      56.3      106.0
                   5/13/93    3      1208-1232       652,372      206.3     15.5      1343.4   43.0      58.1      131.1
                              4      1432-1454       668,090      218.6     16.7      1457.8   40.6      64.8      126.7
                                    1627-1634(p)     348,259      250.2      7.4       869.8   48.8      34.2       79.4
                                                                                               
Baghouse Outlet    5/11/93    1      1715-1733       633,841      155.0     16.2       980.7   34.6      58.8      102.5
                                     1814-1837                    156.4     15.0       989.5   32.6      58.8       96.5
                                    1925-1937(c)     360,038      163.1      4.6       586.2   45.3      28.4       76.2
                                     1945-1958                    156.2     14.8       988.3   35.8      61.6      106.0
                   5/12/93    2      1140-1204       646,910      154.3     12.4       996.4   32.5      55.4       98.2
                                     1251-1315                    157.2     13.0      1015.1   26.7      55.0       80.7
                                     1401-1411                    154.8     11.2       999.6   30.4      50.7       91.9
                                    1420-1438(c)     358,555      177.6      4.6       635.6   34.8      25.9       58.3
                   5/13/93    3      1244-1305       646,269      185.6     15.8      1197.3   42.5      61.1      128.3
                              4      1506-1527       650,288      206.6     16.1      1341.1   40.3      63.6      122.4
                                    1550-1615(p)     348,391      198.8      6.7      1290.4   43.5      31.5       70.8

        Note:  All samples were from the hot/wet system except those designated (c) for the condenser samples
                or (p) for PermaPure&reg samples.  Each concentration is an average calculated from up to four samples.