Technology Transfer Network
Emission Measurement Center Spectral Database
Table 3-2. Summary of Gas Phase FTIR Results From Testing at Kintigh Unit
One
Run Sample Sampling Dilution Sulfur Dioxide Nitric Oxide
Date # Location Time System Factor ppm uncertai lb/hr ppm uncertai lb/hr
------- --- -------- --------- --------- -------- ---- -------- ----- --- -------- -----
7/27/93 1 ESP 1149-1153 Condenser (a) 1253 29 16580 438 53 5803
Inlet 1156-1200 1254 29 16601 434 52 5740
1206-1210 1248 29 16515 435 52 5753
1214-1218 1246 29 16496 439 52 5805
1227-1232 Hot/Wet 1119 33 16271 --- (b) 0
1236-1240 1175 27 17091 --- 0
1245-1247 2 1266 13 18414 522 42 7599
1304-1307 2 1223 12 17788 516 40 7500
1312-1314 Condenser 1233 29 16317 432 53 5720
1317-1320 1231 29 16298 428 52 5662
1324-1327 1228 29 16253 429 52 5682
1331-1334 1234 28 16329 430 53 5686
1342-1345 Hot/Wet 1176 27 17103 --- 0
1349-1353 1160 26 16880 --- 0
1358-1400 2 1202 12 17485 511 41 7428
1412-1414 2 1113 15 16197 466 44 6776
7/28/93 2 ESP 1029-1033 Condenser 1199 23 17052 458 55 6515
Outlet 1042-1046 1209 25 17188 453 54 6447
1052-1056 1208 27 17173 456 54 6480
1102-1105 1210 27 17208 459 54 6531
1110-1113 Hot/Wet 1143 25 17792 --- 0
1115-1118 1140 27 17756 --- 0
1121-1123 2 1190 11 18529 539 43 8394
1131-1132 2 1207 11 18793 540 42 8412
1136-1139 Condenser 1213 26 17247 448 54 6366
1141-1144 1219 27 17329 451 54 6416
1147-1150 1212 27 17229 894 54 ****
1154-1157 1229 27 17481 910 54 ****
1200-1203 Hot/Wet 1156 26 18005 --- 0
1205-1208 1145 27 17826 --- 0
1211-1213 2 1194 11 18597 540 44 8416
1220-1222 2 1212 11 18880 547 44 8525
1441-1445 1136 27 17692 --- 0
1450-1454 1142 28 17784 --- 0
1600-1601 2 1198 12 18656 545 43 8490
1615-1618 2 1326 14 20653 586 45 9119
7/29/93 3 FGD 1036-1042 Condenser 245 4 3788 420 49 6506
Outlet 1049-1053 237 5 3672 422 50 6540
1100-1104 242 5 3745 426 50 6597
1107-1112 240 5 3711 421 50 6523
1125-1129 Hot/Wet 224 11 3991 --- 0
1137-1141 218 11 3889 --- 0
1145-1147 3 256 6 4563 516 29 9184
1208-1210 6.5 269 7 4792 486 19 8659
1218-1222 Condenser 248 5 3836 425 50 6580
1227-1230 246 5 3815 425 50 6589
1238-1241 250 5 3880 424 50 6574
1246-1250 246 5 3815 430 50 6662
1301-1304 Hot/Wet 222 10 3945 --- 0
1308-1312 222 10 3955 --- 0
1321-1326 3 247 6 4402 484 27 8612
----------------------------------------------------------------------------------------------------
(a) A blank space indicates no dilution for that sample.
(b) Interference from water was too great to measure NO in the Hot/Wet undiluted samples.
=====================================================================================================
|