Table 3-2. Summary of Gas Phase FTIR Results from Testing at LILCO Unit One
Run Sample Sampling Dilution Sulfur Dioxide Nitric Oxide
Date # Location Time System Factor ppm uncertai lb/hr ppm uncertai lb/hr
------- --- -------- --------- --------- -------- --- -------- ----- --- -------- ------
7/20/93 1 Outlet 1054-1056 Condenser (a) 389 27 3815 204 66 1999
1102-1104 460 6 4514 211 31 2067
1112-1114 Hot/Wet 2 456 22 3759 247 25 2033
1120-1123 428 31 3526 --- (b) 0
1132-1138 432 20 3560 --- 0
1146-1147 4 496 14 4086 260 14 2138
1204-1208 Condenser 462 6 4528 209 31 2048
1212-1215 465 6 4560 208 31 2038
Inlet 1249-1253 Hot/Wet 478 20 4074 --- 0
1300-1302 484 18 4124 --- 0
1321-1325 Condenser 509 8 5163 230 31 2337
1328-1332 518 8 5258 224 31 2276
1337-1340 514 8 5213 224 31 2274
1346-1349 516 8 5233 222 31 2248
1400-1402 Hot/Wet 4 540 6 4606 266 18 2267
1415-1417 4 494 5 4210 238 16 2025
7/20/93 2 Outlet 1533-1335 Hot/Wet 461 14 3773 --- 0
1538-1539 464 14 3799 --- 0
1543-1544 459 14 3754 --- 0
1548-1550 461 14 3774 --- 0
1554-1557 Condenser 490 7 4773 198 29 1931
1601-1603 484 6 4716 198 29 1931
1606-1608 485 6 4725 200 29 1946
1611-1613 487 7 4741 200 29 1946
Inlet 1742-1747 Condenser 522 7 5326 221 32 2254
1751-1754 522 8 5326 221 32 2248
1759-1802 521 8 5311 221 32 2248
1807-1809 524 8 5341 219 32 2236
1819-1822 Hot/Wet 489 13 4183 --- 0
1826-1829 487 14 4166 --- 0
1835-1836 4 560 7 4796 259 17 2220
1852-1854 4 537 8 4600 244 17 2093
7/21/93 3 Inlet 1032-1035 Condenser 500 5 5235 227 34 2373
1039-1043 503 5 5264 228 35 2387
1047-1052 509 5 5321 228 35 2389
1102-1108 Hot/Wet 486 9 4269 --- 0
1111-1117 2 495 6 4348 237 23 2083
1129-1134 480 10 4215 --- 0
1248-1253 492 12 4326 --- 0
1300-1305 Condenser 516 7 5397 226 33 2365
Outlet 1317-1318 Condenser 470 6 4585 203 31 1981
1327-1329 468 7 4564 203 30 1976
1334-1336 466 6 4542 204 31 1993
1340-1342 465 6 4529 203 31 1980
1355-1359 Hot/Wet 441 10 3610 --- 0
1404-1408 439 9 3592 --- 0
--------------------------------------------------------------------------------------------------
(a) Blank spaces indicate sample was not diluted.