Table 3-3. Concentrations Calculated For Some HAP's That Were Detected in Spectra of Concentrated Samples Extracted From the Unit 5 Stack at Greens Bayou Gas-Fired Boiler


            Nitric Oxide (a)        Ammonia         Hydrogen Chloride      Hexane (b)
           In-Cell   Flue Gas   In-Cell  Flue Gas   In-Cell  Flue Gas   In-Cell  Flue Gas
  Run #    (ppm)(c)  (ppm)(d)    (ppm)    (ppm)      (ppm)    (ppm)      (ppm)    (ppm)
---------  ------------------   -----------------   -----------------   -----------------
    1        21.44    0.2079     5.12     0.0496              0.0000     2.03     0.0197
    2        21.27    0.1768     1.00     0.0083              0.0000     1.82     0.0151
    3        10.65    0.0595     0.49     0.0027              0.0000     1.95     0.0109
Ambient 1             0.0000    12.27     0.0913              0.0000     1.14     0.0085
Ambient 2             0.0000     0.95     0.0071     1.78     0.0133     1.30     0.0097
------------------------------------------------------------------------------------------
(a)  Compounds detected on Tenax&reg for which Entropy has obtained quantitative 
     reference spectra.  Blank spaces indicate a non-detect.
(b)  Probably a mixture of alkane hydrocarbons which may include hexane together
     give absorbances similar to hexane.
(c)  Concentration of detected compound in FTIR cell calculated using MCOMP
     analytical routine.
(d)  Concentration of detected compound in flue gas calculated by dividing 
     in-cell concentration by the concentration factor (see Section 4.6.5).