Technology Transfer Network
Emission Measurement Center Spectral Database
Table 3-8. Validation of O2 and CO2 Measurement Data
Run O2 CO2 Calculated No. (%d) (%d) Fo --- ---- ---- ---------- 1 15.1 3.3 1.76 2 15.1 3.3 1.76 3 15.1 3.4 1.71 Calculated Fo = (20.9-%O2) / %CO2 EPA Method 3 acceptance criteria, Fo range: 1.64 - 1.88 for natural gas |