Parameters With Sampling Methodologies - MET

SORTED ON: Meth Code Ascending

Last Updated on 11/6/2012 at 8:19:15

Download CSV Version of the Code Table

Return to TTN Code Pages

Page: 2 of 2
First Page   Previous Page   Next Page   Last Page
<Parameter Code> <Parameter Desc> <Standard Unit> <Meth Code> <Duration Code> <Duration Desc> <Unit> <Unit Desc> <Collection Desc> <Sample Analysis Disc> <FED MDL> <Summary Scale> <Equivalent Method Desc> <Reference Method ID> <ABS Max Sample Value> <ABS Min Sample Value>
68108 Sample Baro Pressure 059 144 7 24 HOUR 059 Millimeters (mercury) R & P Model 2000 PM-2.5 FEM Audit Sampler Barometric Sensor 450.0 0 None None 850.0 450.0
68105 Ambient Temperature 017 145 7 24 HOUR 017 Degrees Centigrade R & P Model 2025 PM-2.5 FEM Sequential Air Sampler Electronic -40.0 1 None None 55.0 -40.0
68108 Sample Baro Pressure 059 145 7 24 HOUR 059 Millimeters (mercury) R & P Model 2025 PM-2.5 FEM Sequential Air Sampler Barometric Sensor 450.0 0 None None 850.0 450.0
68105 Ambient Temperature 017 153 7 24 HOUR 017 Degrees Centigrade Thermo Electron Model RAAS2.5-100 w/VSCC Electronic -40.0 1 None None 55.0 -40.0
68108 Sample Baro Pressure 059 153 7 24 HOUR 059 Millimeters (mercury) Thermo Electron Model RAAS2.5-100 w/VSCC Barometric Sensor 450.0 0 None None 850.0 450.0
68105 Ambient Temperature 017 154 7 24 HOUR 017 Degrees Centigrade Thermo Electron Model RAAS2.5-200 Audit w/VSCC Electronic -40.0 1 None None 55.0 -40.0
68108 Sample Baro Pressure 059 154 7 24 HOUR 059 Millimeters (mercury) Thermo Electron Model RAAS2.5-200 Audit w/VSCC Barometric Sensor 450.0 0 None None 850.0 450.0
68105 Ambient Temperature 017 155 7 24 HOUR 017 Degrees Centigrade Thermo Electron Model RAAS2.5-300 Sequential w/VSCC Electronic -40.0 1 None None 55.0 -40.0
68108 Sample Baro Pressure 059 155 7 24 HOUR 059 Millimeters (mercury) Thermo Electron Model RAAS2.5-300 Sequential w/VSCC Barometric Sensor 450.0 0 None None 850.0 450.0
68105 Ambient Temperature 017 170 1 1 HOUR 017 Degrees Centigrade Met One BAM-1020 Mass Monitor Electronic 2.0 1 Met One BAM-1020 PM2.5 FEM EQPM-0308-170 1000.0 -10.0
68108 Sample Baro Pressure 059 170 1 1 HOUR 059 Millimeters (mercury) Met One BAM-1020 Mass Monitor Barometric Sensor 2.0 1 Met One BAM-1020 PM2.5 FEM EQPM-0308-170 1000.0 -10.0
62201 Relative Humidity 019 720 7 24 HOUR 019 Percent relative humidity INSTRUMENTAL- COMPUTED(INDIRECT) 0.002 3 None None None None
68105 Ambient Temperature 017 780 7 24 HOUR 015 Degrees Fahrenheit INSTRUMENTAL ELECTRONIC -40.0 1 None None 55.0 -40.0
68105 Ambient Temperature 017 780 7 24 HOUR 017 Degrees Centigrade INSTRUMENTAL ELECTRONIC -40.0 1 None None 55.0 -40.0
68108 Sample Baro Pressure 059 780 7 24 HOUR 022 Inches (mercury) INSTRUMENTAL BAROMETRIC SENSOR 450.0 0 None None 850.0 450.0
68108 Sample Baro Pressure 059 780 7 24 HOUR 059 Millimeters (mercury) INSTRUMENTAL BAROMETRIC SENSOR 450.0 0 None None 850.0 450.0
68105 Ambient Temperature 017 803 7 24 HOUR 015 Degrees Fahrenheit Instrumental Off Site Avg.Temperature -40.0 1 None None 55.0 -40.0
68105 Ambient Temperature 017 803 7 24 HOUR 017 Degrees Centigrade Instrumental Off Site Avg.Temperature -40.0 1 None None 55.0 -40.0
64101 Barometric pressure 016 803 1 1 HOUR 016 Millibars Instrumental Off site baro pressure 0.5 1 None None None 0.0
64101 Barometric pressure 016 803 1 1 HOUR 022 Inches (mercury) Instrumental Off site baro pressure 0.5 1 None None None 0.0
64101 Barometric pressure 016 803 1 1 HOUR 059 Millimeters (mercury) Instrumental Off site baro pressure 0.5 1 None None None 0.0
62101 Outdoor Temperature 015 803 1 1 HOUR 015 Degrees Fahrenheit Instrumental Off Site temperature sensor -60.0 1 None None 150.0 -60.0
62101 Outdoor Temperature 015 803 1 1 HOUR 017 Degrees Centigrade Instrumental Off Site temperature sensor -60.0 1 None None 150.0 -60.0
62101 Outdoor Temperature 015 803 1 1 HOUR 026 Degrees Rankine Instrumental Off Site temperature sensor -60.0 1 None None 150.0 -60.0
62101 Outdoor Temperature 015 803 1 1 HOUR 037 Degrees Kelvin Instrumental Off Site temperature sensor -60.0 1 None None 150.0 -60.0
68108 Sample Baro Pressure 059 803 7 24 HOUR 022 Inches (mercury) Instrumental Off Site Avg. pressure 450.0 0 None None 850.0 450.0
68108 Sample Baro Pressure 059 803 7 24 HOUR 059 Millimeters (mercury) Instrumental Off Site Avg. pressure 450.0 0 None None 850.0 450.0
68105 Ambient Temperature 017 810 7 24 HOUR 017 Degrees Centigrade Met One SASS Electronic -40.0 1 None None 55.0 -40.0
68108 Sample Baro Pressure 059 810 7 24 HOUR 059 Millimeters (mercury) Met One SASS Barometric Sensor 450.0 0 None None 850.0 450.0
68105 Ambient Temperature 017 820 7 24 HOUR 017 Degrees Centigrade Andersen RAAS Electronic -40.0 1 None None 55.0 -40.0
68108 Sample Baro Pressure 059 820 7 24 HOUR 059 Millimeters (mercury) Andersen RAAS Barometric Sensor 450.0 0 None None 850.0 450.0
68105 Ambient Temperature 017 830 7 24 HOUR 017 Degrees Centigrade URG MASS400 WINS Electronic -40.0 1 None None 55.0 -40.0
68108 Sample Baro Pressure 059 830 7 24 HOUR 059 Millimeters (mercury) URG MASS400 WINS Barometric Sensor 450.0 0 None None 850.0 450.0
68105 Ambient Temperature 017 850 7 24 HOUR 017 Degrees Centigrade R&P MDL2300 PM2.5 SEQ SPEC CALCULATION -40.0 1 None None 55.0 -40.0
68108 Sample Baro Pressure 059 850 7 24 HOUR 059 Millimeters (mercury) R&P MDL2300 PM2.5 SEQ SPEC BAROMETRIC SENSOR 450.0 0 None None 850.0 450.0
68105 Ambient Temperature 017 870 7 24 HOUR 017 Degrees Centigrade URG MASS400 VSCC Electronic -40.0 1 None None 55.0 -40.0
68108 Sample Baro Pressure 059 870 7 24 HOUR 059 Millimeters (mercury) URG MASS400 VSCC Barometric Sensor 450.0 0 None None 850.0 450.0
62201 Relative Humidity 019 899 7 24 HOUR 019 Percent relative humidity Unknown-Unknown # 0.002 3 None None None None
68105 Ambient Temperature 017 901 7 24 HOUR 017 Degrees Centigrade BGI Inc. frmOMNI Electronic -40.0 1 None None 55.0 -40.0
68108 Sample Baro Pressure 059 901 7 24 HOUR 059 Millimeters (mercury) BGI Inc. frmOMNI Barometric Sensor 450.0 0 None None 850.0 450.0