Jump to main content or area navigation.

Contact Us

Cranberry (PNF126)

Site Photos
Site Information
Site ID PNF126
Site name Cranberry
County Avery
State abbreviation NC
AQS ID 370119991
Latitude; decimal degrees 36.105435
Longitude; decimal degrees -82.045015
Elevation; m 1216
Operating agency EPA
Start date 09/24/1988
Primary Land Use Forest
Terrain surrounding site Mountaintop
NADP/NTN site ID NC45
Distance to nearest NTN site; km 46.477
Co-located NADP/AMoN Site ID NC02
View Map View Map
Graphical Results
Composition of total nitrogen deposition by species
Trends in total nitrogen deposition
Trends in wet and dry nitrogen deposition
Composition of total sulfur deposition by species
Trends in total sulfur deposition
Trends in wet and dry sulfur deposition
Trend in maximum 8-hour average ozone concentrations
Trend in 3-year average of ozone W126 index
Site History
NOY : Sampling was suspended due to budget constraints. 10-MAY-22
FILTER PACK : Sampling was suspended due to budget constraints. 10-MAY-22
OZONE : Sampling was suspended due to budget constraints. 10-MAY-22
OZONE : Ozone dryer installed 26-JUL-17
SIGMA_THETA : Sensor unwired. 04-FEB-16
WINDSPEED_SCALAR : Sensor unwired. 04-FEB-16
WIND_DIRECTION : Sensor unwired. 04-FEB-16
WINDSPEED : Sensor unwired. 04-FEB-16
TEMP2 : Sensor unwired. 04-FEB-16
RELATIVE_HUMIDITY : Sensor unwired. 04-FEB-16
TEMPERATURE : 9m temperature measurement with passive aspiration installed. 04-FEB-16
OZONE : Air compressor with silica gel and charcoal canisters installed for ozone zero air 15-SEP-15
OZONE : Silica gel canister was added to output of the 701H API Zero Air Box 30-JUN-15
OZONE : New certification range for site transfer standard 23-JUL-14
OZONE : Foam insulation added to sample line. 29-JAN-14
OZONE : Knock-out bottle removed. 29-JAN-14
OZONE : ZSP order changed to SPZ. 18-OCT-13
OZONE : Replacement pressure transducer installed in site analyzer. 03-JAN-12
OZONE : 10 ft. exhaust tubing added to both analyzers. 03-JAN-12
OZONE : Ozone sample line filter removed from inside the shelter. 04-JUL-11
OZONE : Ozone tubing changed from 3/8 inch to 1/4 inch. 23-FEB-11
OZONE : 40CFR Part 58 ozone site upgrade completed using Level 2 site transfer standard. 23-FEB-11
OZONE : 40CFR Part 58 ozone site installed using independent site transfer standard. 20-JUL-10
DATALOGGER : CR3000 datalogger installed. Wiring standardized. 09-JUL-08

Jump to main content.