Contact Us
Technology Transfer Network
Geographic / Ecosystems Initiatives
Severstal North America
- Name of the facility:
- Location:
3001 Miller Rd, Dearborn, MI
- Distance from the US/Canada border:
- Type/size of the facility:
Steel and iron production facility
- Source of emissions:
Blast furnaces, basic oxygen furnace, refining facilities, annealing furnace, slab reheat furnaces
- Type of fuel:
Natural gas and furnace gas
- Type/quantity of mass emission rates
CO: blast furnace stove limits are 13.7 lb/MMscf blast (furnace gas burned) and 84.0 lb/MMscf (natural gas burned), 61.7 lb/hour
SO2: Furnance stove limits are 14.37 lb/MMscf blast furnace gas burned (58.3 lb/hr) and 16.62 lb/MMscf blast furnace gas burned (67.3 lb/hr) if another blast furnace is not operating; 1465 lb/hr
VOC: 4.31 lb/hr
NOx: 13.5 lb/MMscf (furnace gas burned) and 140 lb/MMscf (natural gas burned)
PM and PM10: from 0.0015 gr/dscf to 0.01 gr/dscf, depending on the equipment
- Emission control technology
Low-NOx burners, baghouses, ESP, good combustion practices fuel sulfur content monitoring
- Date permit application received:
- Stack height and diameter:
stacks( minimum heights and maximum diameters are in concordance with 40 CFR 52.21 Subparts (c) and (d).
- Permit agency's contact name, address, telephone number:
Jim Donaldson
Michigan Department of Environmental Quality,
Air Quality Division,
PO Box 30260
Lansing, MI, 48909 - 7760
Tel. 517 241-7470
|