Technology Transfer Network
Emission Measurement Center Spectral Database
Table 3-2. Summary of Gas Phase FTIR Results from Testing at LILCO Unit One
Run Sample Sampling Dilution Sulfur Dioxide Nitric Oxide Date # Location Time System Factor ppm uncertai lb/hr ppm uncertai lb/hr ------- --- -------- --------- --------- -------- --- -------- ----- --- -------- ------ 7/20/93 1 Outlet 1054-1056 Condenser (a) 389 27 3815 204 66 1999 1102-1104 460 6 4514 211 31 2067 1112-1114 Hot/Wet 2 456 22 3759 247 25 2033 1120-1123 428 31 3526 --- (b) 0 1132-1138 432 20 3560 --- 0 1146-1147 4 496 14 4086 260 14 2138 1204-1208 Condenser 462 6 4528 209 31 2048 1212-1215 465 6 4560 208 31 2038 Inlet 1249-1253 Hot/Wet 478 20 4074 --- 0 1300-1302 484 18 4124 --- 0 1321-1325 Condenser 509 8 5163 230 31 2337 1328-1332 518 8 5258 224 31 2276 1337-1340 514 8 5213 224 31 2274 1346-1349 516 8 5233 222 31 2248 1400-1402 Hot/Wet 4 540 6 4606 266 18 2267 1415-1417 4 494 5 4210 238 16 2025 7/20/93 2 Outlet 1533-1335 Hot/Wet 461 14 3773 --- 0 1538-1539 464 14 3799 --- 0 1543-1544 459 14 3754 --- 0 1548-1550 461 14 3774 --- 0 1554-1557 Condenser 490 7 4773 198 29 1931 1601-1603 484 6 4716 198 29 1931 1606-1608 485 6 4725 200 29 1946 1611-1613 487 7 4741 200 29 1946 Inlet 1742-1747 Condenser 522 7 5326 221 32 2254 1751-1754 522 8 5326 221 32 2248 1759-1802 521 8 5311 221 32 2248 1807-1809 524 8 5341 219 32 2236 1819-1822 Hot/Wet 489 13 4183 --- 0 1826-1829 487 14 4166 --- 0 1835-1836 4 560 7 4796 259 17 2220 1852-1854 4 537 8 4600 244 17 2093 7/21/93 3 Inlet 1032-1035 Condenser 500 5 5235 227 34 2373 1039-1043 503 5 5264 228 35 2387 1047-1052 509 5 5321 228 35 2389 1102-1108 Hot/Wet 486 9 4269 --- 0 1111-1117 2 495 6 4348 237 23 2083 1129-1134 480 10 4215 --- 0 1248-1253 492 12 4326 --- 0 1300-1305 Condenser 516 7 5397 226 33 2365 Outlet 1317-1318 Condenser 470 6 4585 203 31 1981 1327-1329 468 7 4564 203 30 1976 1334-1336 466 6 4542 204 31 1993 1340-1342 465 6 4529 203 31 1980 1355-1359 Hot/Wet 441 10 3610 --- 0 1404-1408 439 9 3592 --- 0 -------------------------------------------------------------------------------------------------- (a) Blank spaces indicate sample was not diluted. (b) Water interference was too great to measure NO in hot/wet undiluted samples. |